Computational & AI Journal of Cheminformatics (Springer Nature)

Three ADMET predictors agree with each other but miss measured Caco-2 permeability

  • Three public ADMET platforms (ADMET-AI, ADMETlab 3.0, admetSAR 3.0) were run on a very large natural-product library and mapped to shared endpoints.
  • Caco-2 predictions were then checked retrospectively against measured values for a small set of natural products from one assay program.
  • Platforms agreed with each other yet tracked measured permeability poorly; consensus averaging, size stratification and applicability-domain filters did not clearly help.
Points Based on the abstract

Agreement between tools is mostly shared training data and shared descriptors, so it says nothing about truth. The weaker link is the validation set: a small single-program assay panel is too thin to separate platforms, and natural products likely sit outside every training domain. Anyone relying on these should run their own series' measured Caco-2 through them and compare rank order, not just correlation.